Part Number Hot Search : 
680MZ P6SMB75 0A170 0951F MIC20XX UTC2025 AT89C5 MAX795
Product Description
Full Text Search
 

To Download E200 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 E200 Series
Isolated, Single Output Ultra-Miniature, 2W SIP DC/DC Converters
Electrical Specifications
Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
* 2W Output Power * Ultra-Miniature SIP Case * 1,000 VDC Isolation * >2 MHour MTBF * 18 Standard Models * Industry Standard Pin-Out
Input
Parameter Conditions 5 VDC Input Input Voltage Range 12 VDC Input 24 VDC Input 48 VDC Input Reverse Polarity Input Current Input Filter Internal Capacitor Conditions For Vin Change of 1% Min. Typ. 1.2 100 120 0.01 Momentary (0.5 Sec.) Conditions 60 Seconds 1,000 VDC 100 kHz, 1V Min. 1,000 1,000 60 125 Conditions Ambient Case -55 Free Air Convection RH, Non-condensing 95 % Min. -40 Typ. +25 Max. +85 +90 +125 Typ. Max. Units VDC M pF kHz Units C C C 0.02 Max. 3.0 Units % % mV P - P % %/C Min. 4.5 10.8 21.6 44.0 Typ. 5.0 12.0 24.0 48.0 Max. 5.5 13.2 26.4 52.0 0.3 A Units
VDC
Output
Parameter Output Voltage Accuracy Line Regulation Load Regulation (Note 1) Ripple & Noise (20 MHz) (Note 2) Output Power Protection Temperature Coefficient Output Short Circuit
See Model Selection Guide
RoHS Compliant
General
Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency
Environmental
Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
Physical
Case Size Case Material Weight 0.46 x 0.29 x 0.40 Inches (11.68 x 7.5 x 10.2 mm) Non-Conductive Black Plastic (UL94-V0) 0.06 Oz (1.8g) Conditions MIL HDBK 217F, 25C, Gnd Benign Conditions 5 VDC Input Input Voltage Surge (1 Sec) 12 VDC Input 24 VDC Input 48 VDC Input Lead Temperature Internal Power Dissipation 1.5 mm From Case For 10 Sec All Models Min. 2.0 Min. -0.7 -0.7 -0.7 -0.7 Typ. Max. Units MHours Units
Reliability Specifications
Parameter MTBF
Absolute Maximum Ratings
Parameter Typ. Max. 9.0 18.0 30.0 55.0 260 650 C mW
VDC
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model Number E201 E202 E203 E204 E205 E211 E212 E213 E214 E215 E222 E223 E224 E225 E232 E233 E234 E235 Input Output Load Voltage (VDC) Current (mA) Voltage Current Current Regulation Nominal Range Full-Load No-Load (VDC) (mA, Max) (mA, Min) (% Max) 5 4.5 - 5.5 372 38 3.3 400.0 40.0 12 5 5 5 5 12 12 12 12 12 24 24 24 24 48 48 48 48 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 4.5 - 5.5 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 10.8 - 13.2 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 21.6 - 26.4 44.0 - 52.0 44.0 - 52.0 44.0 - 52.0 44.0 - 52.0 533 500 500 500 150 200 211 199 208 107 102 104 102 53 52 53 52 38 38 38 38 30 30 30 25 25 12 12 12 12 6 6 6 6 5.0 9.0 12.0 15.0 3.3 5.0 9.0 12.0 15.0 5.0 9.0 12.0 15.0 5.0 9.0 12.0 15.0 400.0 222.0 167.0 133.0 400.0 400.0 222.0 167.0 133.0 400.0 222.0 167.0 133.0 400.0 222.0 167.0 133.0 40.0 22.0 16.0 13.0 40.0 40.0 22.0 16.0 13.0 40.0 22.0 16.0 13.0 40.0 22.0 16.0 13.0 12 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Efficiency (%, Typ) 71 75 79 80 80 73 77 79 84 80 78 82 80 82 78 80 78 80 Fuse Rating Slow-Blow (mA) 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 200 200 200 200 100 100 100 100
Notes: 1. Output load regulation is specified for a load change of 20% to 100%. 2. When measuring output ripple, it is recommended that an external 0.33 F ceramic capacitor be placed from the +Vout pin to the -Vout pin. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. The 5V, 12V and 24V input units do not require external components to operate, but the use of a low ESR capacitor (approximately 10 F, ESR <1.0 at 100 kHz) mounted close to the converter input pins is recommended. For 48 VDC input units, an input capacitor should always be used. Dependent upon the application, a value between 4.7 F and 47 F should be sufficient. 5. Out put capacitive load capability of these units is 33 F max. Exceeding this may cause start up problems. 5. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Derating Curve
Pin Connections
Pin 1 2 3 4 Description -Vin +Vin -Vout +Vout
Mechanical Dimensions
Notes:
* All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25) * Pin 1 is marked by a "dot" or indentation on the side of the unit
MicroPower Direct
www.micropowerdirect.com
*
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com